WEG Products

3830 products

  • Weg CWM contactor

    WEG WEG CWM105-11-30V24 105 Amp 3 Pole Contactor with 208-240 VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-11-30V24 Rated Current: 105 Amp Coil Voltage: 208-240 VAC 60Hz / 180-208 VAC 50Hz Number of Power Poles: 3 Pole Auxiliary Contacts: 1 NC 1 NO (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $208.57

  • Weg CWM contactor

    WEG WEG CWM105-11-30V18 105 Amp 3 Pole Contactor with 120 VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-11-30V18 Rated Current: 105 Amp Coil Voltage: 120 VAC 60Hz / 110 VAC 50Hz Number of Power Poles: 3 Pole Auxiliary Contacts: 1 NC 1 NO (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $208.57

  • Weg CWM contactor

    WEG WEG CWM105-00-30V56 105 Amp 3 Pole Contactor with 600 VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-00-30V56 Rated Current: 105 Amp Coil Voltage: 600 VAC 60Hz / 500 VAC 50Hz Number of Power Poles: 3 Pole Auxiliary Contacts: 0 (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $198.47

  • Weg CWM contactor

    WEG WEG CWM105-00-30V47 105 Amp 3 Pole Contactor with 480 VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-00-30V47 Rated Current: 105 Amp Coil Voltage: 480 VAC 60Hz / 400-415 VAC 50Hz Number of Power Poles: 3 Pole Auxiliary Contacts: 0 (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $198.47

  • Weg CWM contactor

    WEG WEG CWM105-00-30V37 105 Amp 3 Pole Contactor with 277 VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-00-30V37 Rated Current: 105 Amp Coil Voltage: 277 VAC 60Hz / 230-240 VAC 50Hz Number of Power Poles: 3 Pole Auxiliary Contacts: 0 (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $198.47

  • Weg CWM contactor

    WEG WEG CWM105-00-30V24 105 Amp 3 Pole Contactor with 208-240 VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-00-30V24 Rated Current: 105 Amp Coil Voltage: 208-240 VAC 60Hz / 180-208 VAC 50Hz Number of Power Poles: 3 Pole Auxiliary Contacts: 0 (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $198.47

  • Weg CWM contactor

    WEG WEG CWM105-00-30V10 105 Amp 3 Pole Contactor with 48VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-00-30V10 Rated Current: 105 Amp Coil Voltage: 48VAC 60Hz / 24 VAC 50Hz Number of Power Poles: 3 Pole Auxiliary Contacts: 0 (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $198.47

  • Weg CWM contactor

    WEG WEG CWM105-00-30V04 105 Amp 3 Pole Contactor with 24 VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-00-30V04 Rated Current: 105 Amp Coil Voltage: 24 VAC 60Hz / 20 VAC 50Hz Number of Power Poles: 3 Pole Auxiliary Contacts: 0 (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $198.47

  • Weg CWM contactor

    WEG WEG CWM105-00-30C34 105 Amp 3 Pole Contactor with 24-28 VDC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-00-30C34 Rated Current: 105 Amp Coil Voltage: 24-28 VDC Number of Power Poles: 3 Pole Auxiliary Contacts: 0 (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $272.70

  • Weg CWM contactor

    WEG WEG CWM105-00-20V24 105 Amp 2 Pole Contactor with 208-240 VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-00-20V24 Rated Current: 105 Amp Coil Voltage: 208-240 VAC 60Hz / 180-208 VAC 50Hz Number of Power Poles: 2 Pole Auxiliary Contacts: 0 (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $162.11

  • Weg CWM contactor

    WEG WEG CWM105-00-20V18 105 Amp 2 Pole Contactor with 120 VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-00-20V18 Rated Current: 105 Amp Coil Voltage: 120 VAC 60Hz / 110 VAC 50Hz Number of Power Poles: 2 Pole Auxiliary Contacts: 0 (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM Contactor Installation Instructions CWM9 to CWM105 WEG CWM Contactor Installation Instructions CWM400 to CWM800 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $162.11

  • Weg CWM contactor

    WEG WEG CWM105-00-20V04 105 Amp 2 Pole Contactor with 24 VAC Coil

    Normally ships within 24 hours

    The WEG CWM contactors are designed for industrial duty reliability. Rated for inductive loads up to 800 Amp, conforming to UL 508, IEC 60947 and CE. A variety of options are available including replacement coils, auxiliary contacts and overloads. Specs Model No: CWM105-00-20V04 Rated Current: 105 Amp Coil Voltage: 24 VAC 60Hz / 20 VAC 50Hz Number of Power Poles: 2 Pole Auxiliary Contacts: 0 (More available as added option) Features 2-pole and 3-pole contactors Panel Mountable on 35mm DIN rails up to CWM105 size Wide range of AC and DC Coils Compact Footprint Easy-to-use accessories through snap-on connectivity Conforms to UL 508, IEC 60947, CE Documentation WEG CWM Flyer WEG CWM Catalog WEG CWM9-105 Installation Instructions 3-D Models and More WEG Downloads

    Normally ships within 24 hours

    $162.11

  • Weg CWB revesing bus bar

    WEG Weg EC-R3 Reversing Bus Bar Kit for CWB95-CWB125 Contactors for CWB Contactors

    Normally ships within 24 hours

    Weg reversing bus bars for CWB contactors provide an easy means of building a reversing contactor for 3-phase electric motors. Compatible Contactors for the EC-R3 Bus bar CWB95, CWB110, CWB125, CWBN3, How to Build a Reversing Contactor Items Needed 2 Weg CWB contactors, appropriately sized for the motor current. 1 Weg IM1 or IM2 interlock, depending on contactor size 1 set of Weg Reversing Bus bars, EC-R1,EC-R2, or EC-R3 (optional-strongly advised) Motor Overload Protection Relay, such as the Weg RW27 or RWB series Steps (see assembly photo): Mount the two CWB contactors side-by-side with the mechanical interlock sandwiched in-between. Attach the bus bar with the two small tabs on the top of the two contactors Attach the bus bar without any tabs to the bottom of the two contactors Connect the two coils up to the appropriate switches or other controls Connect incoming power, appropriately fused, to the top of the left contactor Connect the motor leads to the bottom of the left contactor Optional: Connect overload relay to bottom of left contactor, then connect motor leads to bottom of overload relay. Wire overload relay contacts appropriately with control to the contactor coils (beyond scope of this guide). Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Normally ships within 24 hours

    $46.10

  • Weg CWB revesing bus bar

    WEG Weg EC-R2 Reversing Bus Bar Kit for CWB40-CWB80 Contactors for CWB Contactors

    Ships within 24 hours

    Weg reversing bus bars for CWB contactors provide an easy means of building a reversing contactor for 3-phase electric motors. Compatible Contactors for the EC-R2 Bus bar CWB40, CWB50, CWBN2, CWB65, CWB80, How to Build a Reversing Contactor Items Needed 2 Weg CWB contactors, appropriately sized for the motor current. 1 Weg IM1 or IM2 interlock, depending on contactor size 1 set of Weg Reversing Bus bars, EC-R1,EC-R2, or EC-R3 (optional-strongly advised) Motor Overload Protection Relay, such as the Weg RW27 or RWB series Steps (see assembly photo): Mount the two CWB contactors side-by-side with the mechanical interlock sandwiched in-between. Attach the bus bar with the two small tabs on the top of the two contactors Attach the bus bar without any tabs to the bottom of the two contactors Connect the two coils up to the appropriate switches or other controls Connect incoming power, appropriately fused, to the top of the left contactor Connect the motor leads to the bottom of the left contactor Optional: Connect overload relay to bottom of left contactor, then connect motor leads to bottom of overload relay. Wire overload relay contacts appropriately with control to the contactor coils (beyond scope of this guide). Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $34.58

  • Weg CWB revesing bus bar

    WEG Weg EC-R1 Reversing Bus Bar Kit for CWB9-CWB38 Contactors for CWB Contactors

    Ships within 24 hours

    Weg reversing bus bars for CWB contactors provide an easy means of building a reversing contactor for 3-phase electric motors. Compatible Contactors for the EC-R1 Bus bar CWB9, CWBN00, CWB12, CWB18, CWBN0, CWB25, CWBN1, CWB32, CWB38, How to Build a Reversing Contactor Items Needed 2 Weg CWB contactors, appropriately sized for the motor current. 1 Weg IM1 or IM2 interlock, depending on contactor size 1 set of Weg Reversing Bus bars, EC-R1,EC-R2, or EC-R3 (optional-strongly advised) Motor Overload Protection Relay, such as the Weg RW27 or RWB series Steps (see assembly photo): Mount the two CWB contactors side-by-side with the mechanical interlock sandwiched in-between. Attach the bus bar with the two small tabs on the top of the two contactors Attach the bus bar without any tabs to the bottom of the two contactors Connect the two coils up to the appropriate switches or other controls Connect incoming power, appropriately fused, to the top of the left contactor Connect the motor leads to the bottom of the left contactor Optional: Connect overload relay to bottom of left contactor, then connect motor leads to bottom of overload relay. Wire overload relay contacts appropriately with control to the contactor coils (beyond scope of this guide). Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $27.66

  • Weg BLB suppressor plug-in

    WEG Weg VRB E50 Coil Suppressor Plug-In for CWB Contactors

    Ships within 24 hours

    The Weg CWB Plug-in surge suppressors quench the high voltage spikes inherent in magnetic coils when power is applied or removed. These suppressors help increase the life-splan of relay and switch contacts and protect sensitive electronics which may be used to turn on the contactor. Strongly recommended for applications where the contactor is controlled by a PLC or other electronic means. Weg offers three types: RC-Circuit, Varistor, and Diode. RC circuit types are generally recommended for AC coils. Varistor types can be used for either AC or DC coils. Diode type suppressors are recommended for DC coils only, and polarity must be observed when using the diode plug-in. Catalog No. VRB E50 Suppresor Type Varistor Voltage 130-250VAC, 180-300VDC Compatible with all Weg CWB series contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $13.83

  • Weg BLB suppressor plug-in

    WEG Weg VRB E49 Coil Suppressor Plug-In for CWB Contactors

    Ships within 24 hours

    The Weg CWB Plug-in surge suppressors quench the high voltage spikes inherent in magnetic coils when power is applied or removed. These suppressors help increase the life-splan of relay and switch contacts and protect sensitive electronics which may be used to turn on the contactor. Strongly recommended for applications where the contactor is controlled by a PLC or other electronic means. Weg offers three types: RC-Circuit, Varistor, and Diode. RC circuit types are generally recommended for AC coils. Varistor types can be used for either AC or DC coils. Diode type suppressors are recommended for DC coils only, and polarity must be observed when using the diode plug-in. Catalog No. VRB E49 Suppresor Type Varistor Voltage 12-48VAC, 12-60VDC Compatible with all Weg CWB series contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $13.83

  • Weg BLB suppressor plug-in

    WEG Weg VRB E41 Coil Suppressor Plug-In for CWB Contactors

    Normally ships within 24 hours

    The Weg CWB Plug-in surge suppressors quench the high voltage spikes inherent in magnetic coils when power is applied or removed. These suppressors help increase the life-splan of relay and switch contacts and protect sensitive electronics which may be used to turn on the contactor. Strongly recommended for applications where the contactor is controlled by a PLC or other electronic means. Weg offers three types: RC-Circuit, Varistor, and Diode. RC circuit types are generally recommended for AC coils. Varistor types can be used for either AC or DC coils. Diode type suppressors are recommended for DC coils only, and polarity must be observed when using the diode plug-in. Catalog No. VRB E41 Suppresor Type Varistor Voltage 277-380VAC, 300-510VDC Compatible with all Weg CWB series contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Normally ships within 24 hours

    $13.83

  • Weg BLB suppressor plug-in

    WEG Weg VRB E34 Coil Suppressor Plug-In for CWB Contactors

    Ships within 24 hours

    The Weg CWB Plug-in surge suppressors quench the high voltage spikes inherent in magnetic coils when power is applied or removed. These suppressors help increase the life-splan of relay and switch contacts and protect sensitive electronics which may be used to turn on the contactor. Strongly recommended for applications where the contactor is controlled by a PLC or other electronic means. Weg offers three types: RC-Circuit, Varistor, and Diode. RC circuit types are generally recommended for AC coils. Varistor types can be used for either AC or DC coils. Diode type suppressors are recommended for DC coils only, and polarity must be observed when using the diode plug-in. Catalog No. VRB E34 Suppresor Type Varistor Voltage 50-127VAC, 60-180VDC Compatible with all Weg CWB series contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $13.83

  • Weg BLB suppressor plug-in

    WEG Weg VRB D73 Coil Suppressor Plug-In for CWB Contactors

    Ships within 24 hours

    The Weg CWB Plug-in surge suppressors quench the high voltage spikes inherent in magnetic coils when power is applied or removed. These suppressors help increase the life-splan of relay and switch contacts and protect sensitive electronics which may be used to turn on the contactor. Strongly recommended for applications where the contactor is controlled by a PLC or other electronic means. Weg offers three types: RC-Circuit, Varistor, and Diode. RC circuit types are generally recommended for AC coils. Varistor types can be used for either AC or DC coils. Diode type suppressors are recommended for DC coils only, and polarity must be observed when using the diode plug-in. Catalog No. VRB D73 Suppresor Type Varistor Voltage 400-510VAC Compatible with all Weg CWB series contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $13.83

  • Weg BLB suppressor plug-in

    WEG Weg RCB D55 Coil Suppressor Plug-In for CWB Contactors

    Ships within 24 hours

    The Weg CWB Plug-in surge suppressors quench the high voltage spikes inherent in magnetic coils when power is applied or removed. These suppressors help increase the life-splan of relay and switch contacts and protect sensitive electronics which may be used to turn on the contactor. Strongly recommended for applications where the contactor is controlled by a PLC or other electronic means. Weg offers three types: RC-Circuit, Varistor, and Diode. RC circuit types are generally recommended for AC coils. Varistor types can be used for either AC or DC coils. Diode type suppressors are recommended for DC coils only, and polarity must be observed when using the diode plug-in. Catalog No. RCB D55 Suppresor Type RC Circuit Voltage 50-127V 50/60Hz Compatible with all Weg CWB series contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $13.83

  • Weg BLB suppressor plug-in

    WEG Weg RCB D53 Coil Suppressor Plug-In for CWB Contactors

    Ships within 24 hours

    The Weg CWB Plug-in surge suppressors quench the high voltage spikes inherent in magnetic coils when power is applied or removed. These suppressors help increase the life-splan of relay and switch contacts and protect sensitive electronics which may be used to turn on the contactor. Strongly recommended for applications where the contactor is controlled by a PLC or other electronic means. Weg offers three types: RC-Circuit, Varistor, and Diode. RC circuit types are generally recommended for AC coils. Varistor types can be used for either AC or DC coils. Diode type suppressors are recommended for DC coils only, and polarity must be observed when using the diode plug-in. Catalog No. RCB D53 Suppresor Type RC Circuit Voltage 24-48V 50/60Hz Compatible with all Weg CWB series contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $13.83

  • Weg CWB contactor interlock

    WEG Weg IM2 Interlock for CWB Contactors

    Ships within 24 hours

    The Weg IM1 and IM2 CWB contactor interlocks provide a mechanical means of safety for reversing and star-delta type starters. The interlocks are designed to be "zero-width", which means contactors can be mounted side-by-side without any gap or spacing. The IM1 is for CWB sizes 9 to 38 Amps, and the IM2 is for CWB 40+ amp contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $6.92

  • Weg CWB contactor interlock

    WEG Weg IM1 Interlock for CWB Contactors

    Ships within 24 hours

    The Weg IM1 and IM2 CWB contactor interlocks provide a mechanical means of safety for reversing and star-delta type starters. The interlocks are designed to be "zero-width", which means contactors can be mounted side-by-side without any gap or spacing. The IM1 is for CWB sizes 9 to 38 Amps, and the IM2 is for CWB 40+ amp contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $5.53

  • Weg CWB star-delta bus bar

    WEG Weg EC-SD3 Star-Delta Bus Bar Kit for CWB95-CWB125 Contactors for CWB Contactors

    Normally ships within 24 hours

    The Weg star-delta bus bars for CWB contactors provide an easy means of building a star-delta motor starter for 3-phase electric motors. These re specialized starters used to reduce the start-up in-rush currents on electric motors. A star-delta starter consists of 3 contactors working together to provide the appropriate switching so that the motor starts in a lower-current 'Y' mode, and then switches to 'Delta' mode once full speed is reached.Star-Delta starters should not be used when the motor is controlled by a soft-start or VFD drive. Contactor Model Combinations for the EC-SD3 CWB95/CWB95/CWB95 CWB110/CWB110/CWB95 CWB125/CWB125/CWB95 Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Normally ships within 24 hours

    $62.24

  • Weg CWB star-delta bus bar

    WEG Weg EC-SD2 Star-Delta Bus Bar Kit for CWB50-CWB80 Contactors for CWB Contactors

    Ships within 24 hours

    The Weg star-delta bus bars for CWB contactors provide an easy means of building a star-delta motor starter for 3-phase electric motors. These re specialized starters used to reduce the start-up in-rush currents on electric motors. A star-delta starter consists of 3 contactors working together to provide the appropriate switching so that the motor starts in a lower-current 'Y' mode, and then switches to 'Delta' mode once full speed is reached.Star-Delta starters should not be used when the motor is controlled by a soft-start or VFD drive. Contactor Model Combinations for the EC-SD2 CWB50/CWB50/CWB40 CWB65/CWB65/CWB40 CWB80/CWB80/CWB50 Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $41.49

  • Weg CWB star-delta bus bar

    WEG Weg EC-SD1 Star-Delta Bus Bar Kit for CWB9-CWB38 Contactors for CWB Contactors

    Ships within 24 hours

    The Weg star-delta bus bars for CWB contactors provide an easy means of building a star-delta motor starter for 3-phase electric motors. These re specialized starters used to reduce the start-up in-rush currents on electric motors. A star-delta starter consists of 3 contactors working together to provide the appropriate switching so that the motor starts in a lower-current 'Y' mode, and then switches to 'Delta' mode once full speed is reached.Star-Delta starters should not be used when the motor is controlled by a soft-start or VFD drive. Contactor Model Combinations for the EC-SD1 CWB9/CWB9/CWB9 CWB12/CWB12/CWB9 CWB18/CWB18/CWB12 CWB25/CWB25/CWB18 CWB32/CWB32/CWB18 CWB38/CWB38/CWB25 Documentation Weg CWB Flyer Weg CWB & RW27 Catalog

    Ships within 24 hours

    $34.58

  • Weg URMP undervoltage release

    WEG Weg URMP V47 Undervoltage Release 400-415V 50Hz/480V 60Hz for MPW18-MPW80

    Normally ships within 24 hours

    Undervoltage Release 400-415V 50Hz/480V 60Hz for MPW18-MPW80 Features The URMP trips th MPW when the power voltage drops below the specified voltage Ue. Operating Voltage > 0.85 Ue, trip voltage: 0.35 to 0.7 Ue. Documentation Weg MPW Brochure Weg MPW Flyer

    Normally ships within 24 hours

    $25.82

  • Weg URMP undervoltage release

    WEG Weg URMP V43 MPW100 Undervoltage Release 380-400V 50Hz/460V 60Hz for MPW100

    Normally ships within 24 hours

    Undervoltage Release 380-400V 50Hz/460V 60Hz for MPW100 Features The URMP trips th MPW when the power voltage drops below the specified voltage Ue. Operating Voltage > 0.85 Ue, trip voltage: 0.35 to 0.7 Ue. Documentation Weg MPW Brochure Weg MPW Flyer

    Normally ships within 24 hours

    $25.82

  • Weg URMP undervoltage release

    WEG Weg URMP V37 Undervoltage Release 230-240V 50Hz/277V 60Hz for MPW18-MPW80

    Normally ships within 24 hours

    Undervoltage Release 230-240V 50Hz/277V 60Hz for MPW18-MPW80 Features The URMP trips th MPW when the power voltage drops below the specified voltage Ue. Operating Voltage > 0.85 Ue, trip voltage: 0.35 to 0.7 Ue. Documentation Weg MPW Brochure Weg MPW Flyer

    Normally ships within 24 hours

    $25.82

  • Weg URMP undervoltage release

    WEG Weg URMP V33 MPW100 Undervoltage Release 220-230V 50Hz/240V 60Hz for MPW100

    Normally ships within 24 hours

    Undervoltage Release 220-230V 50Hz/240V 60Hz for MPW100 Features The URMP trips th MPW when the power voltage drops below the specified voltage Ue. Operating Voltage > 0.85 Ue, trip voltage: 0.35 to 0.7 Ue. Documentation Weg MPW Brochure Weg MPW Flyer

    Normally ships within 24 hours

    $25.82

  • Weg URMP undervoltage release

    WEG Weg URMP V30 Undervoltage Release 240V 60Hz for MPW18-MPW80

    Normally ships within 24 hours

    Undervoltage Release 240V 60Hz for MPW18-MPW80 Features The URMP trips th MPW when the power voltage drops below the specified voltage Ue. Operating Voltage > 0.85 Ue, trip voltage: 0.35 to 0.7 Ue. Documentation Weg MPW Brochure Weg MPW Flyer

    Normally ships within 24 hours

    $25.82

  • Weg URMP undervoltage release

    WEG Weg URMP V23 Undervoltage Release 208V 60Hz for MPW18-MPW80

    Normally ships within 24 hours

    Undervoltage Release 208V 60Hz for MPW18-MPW80 Features The URMP trips th MPW when the power voltage drops below the specified voltage Ue. Operating Voltage > 0.85 Ue, trip voltage: 0.35 to 0.7 Ue. Documentation Weg MPW Brochure Weg MPW Flyer

    Normally ships within 24 hours

    $25.82

  • Weg URMP undervoltage release

    WEG Weg URMP V18 MPW100 Undervoltage Release 110V 50Hz/120V 60Hz for MPW100

    Normally ships within 24 hours

    Undervoltage Release 110V 50Hz/120V 60Hz for MPW100 Features The URMP trips th MPW when the power voltage drops below the specified voltage Ue. Operating Voltage > 0.85 Ue, trip voltage: 0.35 to 0.7 Ue. Documentation Weg MPW Brochure Weg MPW Flyer

    Normally ships within 24 hours

    $25.82

  • Weg URMP undervoltage release

    WEG Weg URMP V18 Undervoltage Release 110V 50Hz/120V 60Hz for MPW18-MPW80

    Normally ships within 24 hours

    Undervoltage Release 110V 50Hz/120V 60Hz for MPW18-MPW80 Features The URMP trips th MPW when the power voltage drops below the specified voltage Ue. Operating Voltage > 0.85 Ue, trip voltage: 0.35 to 0.7 Ue. Documentation Weg MPW Brochure Weg MPW Flyer

    Normally ships within 24 hours

    $25.82

  • Weg URMP undervoltage release

    WEG Weg URMP D02 Undervoltage Release 24V 60Hz for MPW18-MPW80

    Ships within 24 hours

    Undervoltage Release 24V 60Hz for MPW18-MPW80 Features The URMP trips th MPW when the power voltage drops below the specified voltage Ue. Operating Voltage > 0.85 Ue, trip voltage: 0.35 to 0.7 Ue. Documentation Weg MPW Brochure Weg MPW Flyer

    Ships within 24 hours

    $25.82


You have seen 756 out of 3830 products

© 2026 Caldwell Electric, Powered by Shopify

    • American Express
    • Apple Pay
    • Diners Club
    • Discover
    • Google Pay
    • Mastercard
    • Shop Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account