Contactor accessories include front and side-mount auxiliary contacts, bus rails, coil surge suppressors, and interlocks. Check out our collections here!
Contactor Accessories
-
Weg Weg DIB-C33 Surge Suppressor Plug-In for CWB Contactors
The Weg CWB Plug-in surge suppressors quench the high voltage spikes inherent in magnetic coils when power is applied or removed. These suppressors help increase the life-splan of relay and switch contacts and protect sensitive electronics which may be used to turn on the contactor. Strongly recommended for applications where the contactor is controlled by a PLC or other electronic means. Weg offers three types: RC-Circuit, Varistor, and Diode. RC circuit types are generally recommended for AC coils. Varistor types can be used for either AC or DC coils. Diode type suppressors are recommended for DC coils only, and polarity must be observed when using the diode plug-in. Catalog No. DIB-C33 Suppresor Type Diode Voltage 12-600VDC Compatible with all Weg CWB series contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog
$13.83
-
WEG WEG BRB-80V24 208-240VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 208-240VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-80D39 480VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 480VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-125E04 24-60V AC/DC coil for CWB95-125,CWBN3 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB95-125 and CWBN3 Contactors Coil Voltage: 24-60V AC/DC Documentation CWB95-125 Coil Installation CWB Flyer CWB Contactors Catalog
$115.25
-
WEG WEG BRB-110D25 240VAC coil for CWB95-110,CWBN3 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB95, CWB110 and CWBN3 Contactors Coil Voltage: 240VAC Documentation CWB95-125 Coil Installation CWB Flyer CWB Contactors Catalog
$25.36
-
WEG WEG BRB-110D15 120VAC coil for CWB95-110,CWBN3 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB95, CWB110 and CWBN3 Contactors Coil Voltage: 120VAC Documentation CWB95-125 Coil Installation CWB Flyer CWB Contactors Catalog
$25.36
-
WEG Weg BFB-22 Front Aux. Contact 2 NO 2 NC for CWB Contactors
The Weg BFB front-mount auxiliary contact block snaps on front of the Weg CWB line of magnetic contactors, extending the number aux. contacts available.Features 2 NO 2 NC Aux. Contacts Compatible with all CWB contactors Documentation CWB Flyer CWB Contactors Catalog
$14.75
-
WEG WEG BCA4-40V24 208-240 VAC coil for CWM32-40 Contactors
WEG CWM replacement coils can be used to replace defective coils, or to change the coil voltage of a CWM contactor. AC and DC coils are not interchangable. Electronic coils accept both AC and DC and have a wider voltage range. Features Replacement Coil for CWM32 to CWM40 Contactors Coil Voltage: 208-240 VAC 60 Hz, 180-208 VAC 50 Hz Documentation WEG CWM Flyer WEG CWM Catalog CWM9-105 Coil Replacement Instructions CWM112-300 Coil Replacement Instructions
$17.68
-
WEG WEG BCXML11 1 NO/1 NC Aux contacts for CWM9-300
WEG CWM auxiliary contacts can be added to front or side of CWM-series contactors for additional control contacts. Features 1 Normally Open (NO) Contact, 1 Normally Closed (NC) Contact Mounts on Left Side Compatible with CWM9 to CWM300 Contactors Terminal Markings to EN 50 005 and EN 50 012 Positive driven contacts in accordance with IEC 60947-4-1 Documentation WEG CWM Flyer WEG CWM Catalog
$11.11
-
WEG WEG BCXMF10 Front-Mount 1 N.O. Aux contact for CWM9-105
WEG CWM auxiliary contacts can be added to front or side of CWM-series contactors for additional control contacts. Features 1 Normally Open (NO) Contact Mounts on Front Compatible with CWM9 to CWM105 Contactors Terminal Markings to EN 50 005 and EN 50 012 Positive driven contacts in accordance with IEC 60947-4-1 Documentation WEG CWM Flyer WEG CWM Catalog
$5.05
-
WEG WEG BAMRC9 D63 Coil Surge Suppressor 130-250 VAC for CWM50-105 Contactors
WEG coil supresssors are used to reduce coil kickback voltages when the coil is de-energized. They help protect sensitive driving electronics and extend coil life. Features Compatible with CWM50 to CWM105 Contactors Suppresses voltage spikes from coil operation Protects sensitive coil activation electronics Reduces EMI during coil operation. Documentation WEG CWM Flyer WEG CWM Catalog
$15.15
-
WEG WEG BAMRC5 D55 Coil Surge Suppressor 50-127 VAC for CWM9-40 Contactors
WEG coil supresssors are used to reduce coil kickback voltages when the coil is de-energized. They help protect sensitive driving electronics and extend coil life. Features Compatible with CWM9 to CWM40 Contactors Suppresses voltage spikes from coil operation Protects sensitive coil activation electronics Reduces EMI during coil operation. Documentation WEG CWM Flyer WEG CWM Catalog
$15.15
-
WEG Weg RCB D63 Coil Suppressor Plug-In for CWB Contactors
The Weg CWB Plug-in surge suppressors quench the high voltage spikes inherent in magnetic coils when power is applied or removed. These suppressors help increase the life-splan of relay and switch contacts and protect sensitive electronics which may be used to turn on the contactor. Strongly recommended for applications where the contactor is controlled by a PLC or other electronic means. Weg offers three types: RC-Circuit, Varistor, and Diode. RC circuit types are generally recommended for AC coils. Varistor types can be used for either AC or DC coils. Diode type suppressors are recommended for DC coils only, and polarity must be observed when using the diode plug-in. Catalog No. RCB D63 Suppresor Type RC Circuit Voltage 130-250V 50/60Hz Compatible with all Weg CWB series contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog
$13.83
-
WEG Weg DIZB C26 Coil Suppressor Plug-In for CWB Contactors
The Weg CWB Plug-in surge suppressors quench the high voltage spikes inherent in magnetic coils when power is applied or removed. These suppressors help increase the life-splan of relay and switch contacts and protect sensitive electronics which may be used to turn on the contactor. Strongly recommended for applications where the contactor is controlled by a PLC or other electronic means. Weg offers three types: RC-Circuit, Varistor, and Diode. RC circuit types are generally recommended for AC coils. Varistor types can be used for either AC or DC coils. Diode type suppressors are recommended for DC coils only, and polarity must be observed when using the diode plug-in. Catalog No. DIZB C26 Suppresor Type Diode Voltage 12-250VDC Compatible with all Weg CWB series contactors. Documentation Weg CWB Flyer Weg CWB & RW27 Catalog
$13.83
-
WEG WEG BRB-80D98 277VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 277VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-80D77 208VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 208VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-80D45 600VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 600VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-80D35 415VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 415VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-80D33 380VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 380VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-80D24 230VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 230VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-80D15 120VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 120VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-80D07 48VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 48VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-80D02 24VAC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 24VAC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$18.44
-
WEG WEG BRB-80C03 24VDC coil for CWB40-80,CWBN2 Contactors
WEG CWB coils can be used to replace defective coils, or to change the coil voltage of a CWMB contactor. AC and DC coils are not interchangeable.Features Replacement Coil for CWB40-80 and CWBN2 Contactors Coil Voltage: 24VDC Documentation CWB40-80 Coil Installation CWB Flyer CWB Contactors Catalog
$50.71
You have seen 24 out of 153 products